Komatsu — 4.17.5. MULTI-PURPOSE BUCKET CONTROL LEVER POSITIONS (IF EQUIPPED)

SECTION 4 OPERATING Page 38 LOADER OPERATIONS 4.17.4. AUTOMATIC BUCKET LEVELER Fig. 4.32. Automatic Bucket Leveler 1. Trip Bar 2. Proximity Switch with Adjustment Nut C. Bar-To-Switch Clearance The automatic bucket leveler is located on the underside of the bucket cylinder and is preset to stop the bucket in the horizontal or digging position. Trip bar (1) is attached to the cylinder rod. The trip bar moves with the cylinder rod. Proximity switch (2) creates a magnetic field circuit which is completed by the proximity of trip bar (1) within the magnetic field. Once the bucket is dumped, move the bucket control lever to its detented "ROLL BACK" position.

When the bucket reaches its preset position, trip bar (1) has moved out of the magnetic field circuit created by the proximity switch; it will automatically stop and the bucket control lever will return to the "HOLD" position. Bar- to-switch clearance "C" necessary for the proper operation of the proximity switch is 7 [mm] to 8 [mm]. It is adjusted with the proximity switch nuts. ADJUSTMENT OF AUTOMATIC BOOM KICK-OUT Place the bucket flat on the ground. Place the key in the starting switch in the "RUN" position. If the electromagnetic field of proximity switch (2) is making contact with trip bar (1) mounted under the cylinder rod, the bucket control lever will stay in the "HOLD" position.

Slide the proximity switch mounting "U" bolt back toward the base end of cylinder until contact of the electro-magnetic field is broken. This will be the kick-out position for a level bucket. 4.17.5. MULTI-PURPOSE BUCKET CONTROL LEVER POSITIONS (IF EQUIPPED) The multi-purpose bucket control lever controls the opening and closing of the clam on the bucket. Before changing the bucket position raise the bucket 1 [m] above the ground. In standard version it is located next to the bucket control lever closest to the operator’s seat 28, Fig. 4.4). In upgraded version it is located on the right of the bucket and boom control lever (28, Fig. 4.5).

OPEN Push the control lever forward to open the bucket clam. When released, the lever will automatically return to the "HOLD" position. HOLD The control lever will return automatically to the "HOLD" position from either the "OPEN" or "CLOSE" position when released. The bucket clam will remain in the same position it was in when the control lever was released. OM515C520C99/1E DRESSTA