2000 Hour Service 30. Start engine and run at 1500 rpm for a minimum of 15 minutes. CAUTION: Explosive release of fluids from pressurized cooling system can cause serious burns. Shut off engine. Only remove cap when cool enough to touch with bare hands. Slowly loosen cap to first stop to relieve pressure before removing completely. TS281 —UN—23AUG88 31. Turn off engine, allow coolant to cool, raise hood, remove side panel, then using previously listed steps, drain system. 32. Using previous steps, remove clamps, hoses, tube and braces. 4. With deaeration tank cap ON and hood closed, start engine and run at idle for 1 to 5 minutes. Install New Thermostats 5.
Shut off engine, raise hood, remove deaeration tank cap. Top off high pressure circuit at deaeration tank and reinstall cap. 1. Remove thermostat cover and clean sealing area. 2. Apply RTV silicone sealant to new gasket. 3. Install new thermostats, new gasket and cover. Tighten cap screws to specifications. 6. Close hood, start engine and warm up for 15 minutes. If the coolant recovery tank loses coolant to the ground, repeat previous step and top off until it does not. Loosing coolant to the ground indicates air in high pressure circuit is being discharged through coolant recovery bottle.
Specification Thermostat Cover Cap Screws—Torque .............................................................. 48 (35 lbft) 7. Shut off engine and allow to cool. Observe coolant level dropped below Full Hot in the recovery tank. 4. Using previously listed sequence, install hoses, clamps, tube, cap screws and brace. NOTE: If coolant level did not drop below Full Hot , there is a leak in cooling system that could lead to engine damage. 5. Install fan guard and side panel. 8. Monitor coolant recovery tank level for the next two days of use. Refill coolant recovery tank as required. 6. Close radiator and engine drain valves. Fill Cooling System IMPORTANT:
Use coolant as specified in Fuel, Lubricants and Coolant section. NOTE: It is normal for level to go down with the first few cycles and then range somewhere between Full Hot and Full Cold. 1. Fill high pressure coolant circuit at deaeration tank. NOTE: It is normal for deaeration tank to be partially full of air when cap is removed and system completely deaerated. When inspecting tank, if it is at least half full, do not add additional coolant. Topping off tank may cause coolant to be expelled onto the ground and/or cavitation of water pump. 2. Begin filling coolant recovery tank. When air is purged and coolant is visible, close EGR cooler vent plug. 3.
Finish filling coolant recovery tank to Full Hot mark. NOTE: Coolant level in recovery tank will drop the first few cycles unless there is a leak. Continued on next page OURX935,00004A7 1912DEC085/6 1075 122208 PN=295