Komatsu — WHEN REQUIRED

WHEN REQUIRED b. CHECK, CLEAN AND REPLACE AIR CLEANER ELEMENT Checking Cleaning or replacing outer element Replace the outer element which has been cleaned 6 times repeat- edly or used throughout a year. Replace the inner element at the same time. Replace both inner and outer ele- ments when the dust indicator red piston appears soon after install- ing the cleaned outer element even though it has not been cleaned 6 Whenever the red piston in dust indicator (1) appears, clean the air .cleaner outer element. Stop the en- gine when cleaning the element. element (3). Clean the air cleaner body interior and the removed cover. Clean and inspecttheelement.

(See the item “Cleaning outer element” Remove wing nut (2) and outer times. Remove one seal from the outer element. The number of times the outer element has been cleaned for cleaning procedure.) Install the cleaned element. Push the dust indicator reset but- ton to return the red piston to the original position. can be seen by the number of removed seals. -119-