mercedes-benz — Mercedes-Benz Automated-Manual Transmissions Troubleshooting Guide

Cab Heater and Air Conditioner, Valeo 83.00 Troubleshooting If a leak exists in the system and it cannot be traced to other parts or fittings, suspect damage to one of the evaporator coils. Condenser Temperature Blend Door Actuator Circuit Tests The temperature blend door actuator controls the amount of air that is routed through the heater core. The temperature blend door actuator is controlled by the temperature control switch on the control head (climate control panel). The control head senses the door position by reading the feedback voltage from the actuator position sensor. The feedback voltage will be less than the 5V reference voltage sent by the control head to the sensor.

The condenser is usually trouble-free. Normally, the temperature of the condenser outlet line is noticeably cooler than the inlet line. However, when road debris such as leaves or dirt build up, the airflow over the condenser fins is blocked. Air is not able to absorb enough heat to turn the hot refrigerant gas into a liq- uid. High head pressures will result. In these cases, carefully clean the outer surfaces of the condenser with compressed air or a soap and water solution. Be careful not to bend the fins. The target position is based on the temperature con- trol switch setting and internal control head algo- rithms.

The desired position is considered reached when one of the following conditions is true, although this does not necessarily mean that the position actu- ally corresponds to the desired temperature setting (for example, if the actuator movement is limited due to an obstruction). High head pressures will also occur if the condenser tubing is abnormally bent, blocking the flow of refrig- erant. Frost will appear at the point where the flow is restricted. Less common internal blockages, such as bits of for- eign material or metallic grit buildup, will stop the flow of refrigerant. The actuator feedback position has been reached.

When troubleshooting a suspected condenser prob- lem, remember that the problem may be caused by the radiator transferring high levels of heat to the condenser. See Group 20 of this manual for cooling system troubleshooting, and see the engine manu- facturer’s service manual for other information about cooling system problems. Line Restrictions The actuator is stalled for more than 1 second; the actuator feedback position does not change for more than 1 second. The target position corresponds to an end stop and an additional 1 second extra drive in the same direction (to guarantee sealing) has been performed.

The temperature blend door should move from one extreme position to the other when turning the tem- perature control switch from cold to hot or from hot to cold. A restricted suction line causes low suction pressure at the compressor and little or no cooling. A restric- tion in a line between the compressor and the expan- sion valve can cause high discharge and low suction pressure, and insufficient cooling. Follow the tests in Table 3 in the sequence pre- sented. The directions under the column "What to Do if Test Fails" are sometimes dependent on good re- sults from previous tests. If any of the tests fail, stop and perform the specified repair or check.

If the tem- perature blend door actuator passes the tests in Table 3 and the actuator still does not operate prop- erly, check for mechanical problems with the actua- tor. Areas of ice or frost buildup usually mean a block- age. Parts that often freeze are probably corroded or inoperative and should be replaced. Parts, such as the expansion valve, that freeze once in a while may do so because of moisture in the system. If this hap- pens, recover the refrigerant charge, evacuate/ recycle the system refrigerant, replace the receiver- drier, and recover, evacuate, and charge the system with refrigerant. Business Class M2 Workshop Manual, Supplement 13, March 2008 300/8