Meritor WABCO Pneumatic Antilock Braking System (ABS) 42.00 ABS System Troubleshooting Left Rear Modulator Valve Troubleshooting (SID 009) MID SID FMI Problem Test Test Result Action 136 009 06 Short to ground 3. Check the modulator valve inlet and outlet circuit resistance. Disconnect the connector from the valve and perform the modulator valve test. Resistance in both circuits is within 4 to 8 ohms. Check harness wiring circuits 378LRI, 378LRO, and 378LR– for short to ground. Repair as necessary. Inlet or outlet circuit shorted to ground. Resistance in both circuits is not within 4 to 8 ohms. Replace modulator valve.
Table 8, Left Rear Modulator Valve Troubleshooting (SID 009) Right Rear Modulator Valve Troubleshooting (SID 010) MID SID FMI Problem Test Test Result Action 136 010 03 Short to power 1. Measure the voltage between pins 7, 8, and 9 of the X3 (green) connector and a good chassis ground. No voltage at either pin Repeat test. Check circuits 378RRO, 378RR–, and 378RRI for intermittent short to power. Check above circuits for shorts to other modulator valve wires. Repair as necessary. Inlet or outlet circuit shorted to battery supply or another modulator valve wire. If problem persists, the suspect ECU is at fault.
Measurable voltage at either pin Repair short to power in circuit 378RRO, 378RR–, or 378RRI. 136 010 05 Open circuit 2. Check the modulator valve inlet and outlet circuit resistance. Disconnect the connector from the valve and perform the modulator valve test. Resistance in both circuits is within 4 to 8 ohms. Check harness wiring circuits 378RRO, 378RRI, and 378RR–. Inlet or outlet circuit open. Resistance in both circuits is not within 4 to 8 ohms. Replace the modulator valve. 136 010 06 Short to ground 3. Check the modulator valve inlet and outlet circuit resistance. Disconnect the connector from the valve and perform the modulator valve test.
Resistance in both circuits is within 4 to 8 ohms. Check harness wiring circuits 378RRI, 378RRO, and 378RR– for short to ground. Repair as necessary. Inlet or outlet circuit shorted to ground. Resistance in both circuits is not within 4 to 8 ohms. Replace modulator valve. Table 9, Right Rear Modulator Valve Troubleshooting (SID 010) Business Class M2 Workshop Manual, Supplement 2, June 2002 300/11