Meritor WABCO Pneumatic Antilock Braking System (ABS) 42.00 ABS System Troubleshooting J1939 Datalink Troubleshooting (SID 231) MID SID FMI Problem Test Test Result Action 136 231 07 J1939 time out Check the driveline retarder ECU and wires. Check J1939 datalink and driveline retarder ECU. Repair as necessary. NOTE: Fault occurs if engine retarder sends message incorrectly. Freightliner SB 54-133 136 231 08 J1939 time out Check engine ECU and wires. Check J1939 datalink. Check J1939 datalink and engine ECU. Repair as necessary. NOTE: Fault occurs if engine retarder sends message incorrectly. Freightliner SB 54-133 136 231 09 J1939 time out Check engine and transmission ECUs and wires.

Check J1939 datalink. Check J1939 datalink, engine ECU, transmission ECU, and wiring. Repair as necessary. NOTE: Fault occurs if engine retarder sends message incorrectly. Freightliner SB 54-133 136 231 10 J1939 time out Check the engine ECU and wires. Check the J1939 datalink. Check J1939 datalink and engine ECU. Repair as necessary. NOTE: Fault occurs if the exhaust retarder sends a message incorrectly. Freightliner SB 54-133 136 231 12 J1939 internal error Verify fault. Clear code from the ECU memory. If fault persists, replace the ABS ECU.

Table 14, J1939 Datalink Troubleshooting (SID 231) Voltage Troubleshooting (SID 251) MID SID FMI Problem Test Test Result Action 136 251 03 Overvoltage Using Meritor PC Diagnostics, check the diagonal voltages with the engine running at governed speed, or measure the voltage at the batteries with the engine running at governed speed. Voltage is 9.5 to 14 volts Check for intermittent sources of high voltage. Check condition of charging system and batteries. Verify fault. Voltage to ECU was too high for more than 5 seconds. Voltage is greater than 14 volts. Check charging system. Repair as necessary.

Table 15, Voltage Troubleshooting (SID 251) Business Class M2 Workshop Manual, Supplement 2, June 2002 300/15