Meritor WABCO Hydraulic Antilock Braking System (ABS) 42.26 Troubleshooting J1587 Fault 136-023 ABS Warning Light MID SID FMI Problem Test Test Result Action ABS light illuminates Check circuit 376L for open circuit between splice S22 and X2/8 at the ABS connector. Repair as necessary. 136 023 05 Open circuit or low current 1. Disconnect the black X2 connector from the ECU. Turn the ignition ON. Check the bulb and wire (circuit 376L between splice S22 and ICU pin B11. If okay, replace the ICU.
ABS light does not illuminate Table 10, J1587 Fault 136-023 ABS Warning Light MID SID FMI Problem Test Test Result Action J1587 Fault 136-030 Recirculation Pump Relay Voltage zero If the problem persists, suspect the ECU is at fault. 1. Disconnect the black X2 ECU connector. With the ignition ON, measure the voltage between Pin 6 and a good chassis ground. 136 030 03 Relay shorted to power Voltage not zero Circuit 376H is shorted to power. Repair as necessary. Resistance between 50 and 200 ohms If the problem persists, suspect the ECU is at fault. 2. Disconnect the black X2 ECU connector. Measure the resistance between Pin 6 and a good chassis ground.
Check the relay coil, relay coil ground circuit, and Circuit 376H for an open circuit. Repair as necessary. 136 030 05 Relay open circuit Resistance below 50 or above 200 ohms Resistance between 50 and 200 ohms If the problem persists, suspect the ECU is at fault. 3. Disconnect the black X2 ECU connector. Measure the resistance between Pin 6 and a good chassis ground. 136 030 06 Relay short to ground Resistance below 50 or above 200 ohms Check Circuit 376H for a short to ground. Repair as necessary. Business Class M2 Workshop Manual, Supplement 4, March 2003 300/16