daewoo Solar 140LC-V — Check for Leaks In Fuel System

CHECK FUEL LEVEL WARNING! Use extreme safety precautions while refueling to prevent explosions or fire. Immediately clean up any spilt fuel. 1. At end of each work day, fill fuel tank. Add fuel through fuel fill tube (1, Figure 18). When working at a temperature of 0°C (32°F) or higher, use ASTM No. 2-D or its equivalent. At temperatures below 0°C (32°F) use ASTM No. 1-D or its equivalent. Figure 18 2. Make sure that the fuel fill hose is grounded to the excavator before fueling begins. 3. Check the amount of fuel in the tank by observing the fuel tank sight gauge (2, Figure 18). NOTE: See “Fluid Capacities” on page 4-7. for capacity. 4.

The excavator may be equipped with the optional battery operated fuel fill pump. The pump assembly is in the hydraulic pump compartment. Put the suction hose of the pump into the fuel resupply tank. Turn the switch in the battery box "ON," and the fuel will be pumped into the excavator fuel tank. 5. Do not overfill the tank. 6. Securely tighten cap after fueling. NOTE: If breather holes in cap are clogged, a vacuum may form in the tank preventing proper fuel flow to engine. Keep holes in fuel cap clean. CHECK FOR LEAKS IN FUEL SYSTEM 1. Perform an inspection of the engine compartment to verify that the fuel system is not leaking. If any is noted, determine the source of the leak and repair.

HAOC510L Figure 19 022-00058E Operation and Maintenance Manual Inspection, Maintenance and Adjustment 4-15