250 HOUR / MONTHLY SERVICE PERFORM ALL DAILY AND 50 HOUR SERVICE CHECKS CHANGE SWING REDUCTION DEVICE OIL (DRAIN AND REFILL AFTER FIRST 250 HOURS) NOTE: Change swing reduction device oil after first 250 hours on a new machine and every 1,000 hours thereafter (See page 4-39). CLEAN OUTER FILTER OF TWO STAGE AIR CLEANER 02/05 [MO] 11:30A WARNING! 2059 RPM Never clean or attempt to remove the air cleaner filter if the engine is running. Air Cleaner CLOGGED!! If using compressed air to clean the element, make sure that proper eye protection is worn. ARO0210L Figure 42 1. Locate the air filter assembly. Remove access cover (1, Figure 43) and outer filter from air filter assembly. NOTE:
If indicator light (Figure 42) on instrument panel comes "ON" the air cleaner must be serviced. NOTE: Replace outer filter every 500 hours / 3 months of service. 2. Remove and clean rubber evacuator valve (2, Figure 43) from bottom of air cleaner housing. Inspect seal lips for wear or damage. Replace valve if necessary. Figure 43 3. Clean the outer filter by blowing compressed air from the inside of the filter towards the outside. Do not use more than 205 kPa (30 psi) air pressure. 4. Clean the inside of the air filter housing and the inside of the air filter housing cover. 5. Properly reinstall the air filter and cover. Tighten the cover wing nut finger tight.
Do not use any tools to tighten the wing nut. HAOC570L Figure 44 4-26 Inspection, Maintenance and Adjustment 022-00058E Operation and Maintenance Manual