HANDLING OF ACCUMULATOR WARNING! Even though the engine is stopped, the hydraulic accumulators for the pilot system are still charged. Do not disconnect any pilot system hoses until accumulator pressure has been released from the circuit. To release pressure, turn the starter switch to “I” (ON) position and operate all hydraulic control levers and forward/reverse travel levers. Even though the engine is shut down, hydraulic actuated components may move while releasing pilot pressure. Keep all personnel away from excavator while performing this operation. Set safety lever on "LOCK" position after stopping engine. Do not mishandle accumulator(s).
They are very dangerous because they contain high-pressure nitrogen gas. Do not punch a hole or apply heat or fire to an accumulator. Do not weld on accumulator, or try attaching anything to it. When replacing an accumulator, contact a DAEWOO distributor or sales agency so the gas can be properly released. Wear safety goggles and protective gloves when working on an accumulator. Hydraulic oil under pressure can penetrate the skin and cause serious injuries. Release pilot accumulator pressure using the following procedure; 1. Lower front attachment (bucket) to the ground. 2. Shut down engine. 3. Set safety lever on "RELEASED" position. 4. Turn starter switch "ON." 5.
Fully stroke work and travel levers in all directions. 6. Set safety lever on "LOCK" position. Figure 95 7. Turn key to "OFF" position and remove from starter switch. 8. Remove accumulator by unscrewing it slowly. 4-66 Inspection, Maintenance and Adjustment 022-00058E Operation and Maintenance Manual