daewoo Solar 140LC-V — Long Term Storage

LONG TERM STORAGE Perform the following if storing the excavator for more than one month. 022-00058E Operation and Maintenance Manual Inspection, Maintenance and Adjustment 4-67 Conditions Maintenance Required 1. Cleaning 1. Pressure wash the undercarriage and track assemblies. Inspect for damage or loose or missing parts. 2. Lubrication 1. Perform all daily lubrication procedures. 2. Apply a coating of light oil to the exposed plated metal surfaces, such as hydraulic cylinder rods, etc. 3. Apply a coating of light oil to all of the control linkages and control cylinders (control valve spools, etc.). 3. Battery 1.

Remove the battery from the excavator or remove the battery leads from the battery to fully charge and store. 4. Cooling System 1. Inspect the coolant recovery tank to make sure that the antifreeze level in the system is at the correct level. 2. Every 90 days, use a hydrometer to measure the protection level of the coolant. Refer to the antifreeze/coolant protection chart to determine the amount of protection the cooling system requires. Add coolant as required. 5. Hydraulic System 1. Once a month, start the engine and follow the "Hydraulic Oil Warm-up" procedures listed in this manual.