Kubota — 2. Cleaning air cleaner primary element

EVERY 100 HOURS PERIODIC SERVICE (1) Grease fitting (top link) (2) Grease fitting (top link bracket) (3) Grease fitting (lifting rod) (1) Battery terminals 2. Cleaning air cleaner primary element NOTE : If the air conditioner condenser is pulled out when cleaning the air cleaner, the air cleaner cover can be detached and attached easily. (See Cleaning grill, radiator screen, oil cooler, fuel cooler, air conditioner condenser and battery mount on page 107.) 1. Remove the air cleaner cover and primary element. 2. Clean the primary element: When dry dust adheres to the element, blow compressed air from the inside, turning the element.

Pressure of compressed air must be under 205 kPa (2.1 kgf/cm 2 , 30 psi). When carbon or oil adheres to the element, soak the element in detergent for 15 minutes, then wash it several times in water, rinse with clean water and dry it naturally. After the element has fully dried, inspect inside the element with a light and check for damage. (1) Grease fitting (hydraulic lift cylinders pin) (1) Grease fitting (steering joint shaft) M5091N, M5101N 113