Kubota — 7.2 Charging the battery

EVERY 100 HOURS PERIODIC SERVICE shorten the battery's service life or cause an explosion. Check the fluid level regularly and add distilled water as required so that the fluid level is between the [UPPER] and [LOWER] levels. NOTE : When viewing the indicator, check from directly above by removing the air cleaner cover or using a mirror. WARNING To avoid personal injury or death: Never remove the battery cap while the engine is running. Keep electrolyte away from eyes, hands and clothes. If you are spattered with it, wash it away completely with water immediately and get medical attention. Keep open sparks and flames away from the battery at all times.

Hydrogen gas mixed with oxygen becomes very explosive. Wear eye protection and rubber gloves when working around the battery. 7.2 Charging the battery WARNING To avoid personal injury or death: When the battery is being activated, hydrogen and oxygen gases in the battery are extremely explosive. Keep open sparks and flames away from the battery at all times, especially when charging the battery. When charging the battery, ensure the vent caps are securely in place (if equipped). When disconnecting the cable from the battery, start with the negative terminal first. When connecting the cable to the battery, start with the positive terminal first.

Never check battery charge by placing a metal object across the posts. Use a voltmeter or hydrometer. NOTE : The factory-installed battery is a non-refillable type. If the indicator turns white, do not charge the battery but replace it with a new one. Mishandling the battery shortens the service life and adds to maintenance costs. The original battery is maintenance free, but needs some servicing. If the battery is weak, the engine will be difficult to start and the lights will be dim. It is important to check the battery periodically. (1) Battery 1.

To slow charge the battery, connect the battery positive terminal to the charger positive terminal and the negative to the negative, then recharge in the standard fashion. 2. A boost charge is only for emergencies. It will partially charge the battery at a high rate and in a short time. When using a boost-charged battery, it is necessary to recharge the battery as early as possible. Failure to do this will shorten the battery's service life. 3. The battery is charged when the indicator display turns from black to green. (1) Battery (2) Indicator 7.1 How to read indicator Check the battery condition by reading the indicator.

M5091N, M5101N 117 Green Specific gravity of electrolyte and quality of elec- trolyte are both in good condition. Black Battery needs charging. White Battery needs replacing.