Kubota — 1. RPM dual memory setting

OPERATING THE TRACTOR ELECTRONIC ENGINE CONTROL ELECTRONIC ENGINE CONTROL The electronically controlled engine which is installed in this tractor performs the following 2 types of control. 1. RPM dual memory setting 2. Constant RPM Management control 1. RPM dual memory setting Two different engine speeds can each be set with a single touch by pressing the RPM dual memory switch to the (A) or (B) side. This can be used to eliminate troublesome acceleration operations. Keep the hand throttle lever above the minimum speed. At the minimum speed, a memory setup cannot be performed. You can also depress the foot throttle to increase the engine speed above the set speed.

(1) RPM dual memory switch (A) Switch A (B) Switch B Setting the speeds or changing the speed settings Setting RPM dual memory switch (A). Example of use Consider an example in which an engine speed of 2000 rpm is set for the switch (A) side and a speed of 1000 rpm is set for the switch (B) side. 1. Turn the key switch to . The speed setting can be made both when the engine is running and when it is stopped. 2. Set the hand throttle lever slightly toward the higher-speed side. 62 M5091N, M5101N Work During work, simply press the switch to the (A) side to auto- matically set an engine speed of 2000 rpm.

Turning When turning, press the switch to the (B) side to lower the speed to 1000 rpm, allowing turning at low speed. Work After turning, press the switch again to the (A) side to resume a speed of 2000 rpm.