Komatsu — EVERY 1000 HOURS SERVICE

. MAINTENANCE SERVICE PROCEDURE CHANGE OIL IN TRANSMISSION CASE, CLEAN STRAINER WARNING (5) with a new one, install cover (5), and tighten bolt (4). 4 - 65 The parts and oil are at high tempe rature immediately after the engine is stopped, and may cause burn s. Wait for the temperature o go down before starting the wo Refill amount of oil: 45 liters 1. Set a container under the transmission case to catch the 2. Remove drain plug (1). To prevent the oil from spu rting out, gradually loosen drain p lug (2). 3. After draining the oil, tighte n drain plug (2) and install drain p lug (1). Tightening torque drain plug (1): 59 to 78. 5 Nm (6 to 8 kgm, 43.4 to 57.9 lbft) drain plug (2): 49 to 78.

5 Nm (5 to 8 kgm, 36.2 to 57.9 lbft) drain plug (3): 9.8 to 12. 7 Nm (1.0 to 1.3 kgm, 7.2 to 9.4 lbft) 4. Remove drain plug (3) and drain the oil. 5. Remove bolt (4) to take co ver (5) off, and take strainer (7) out to wash it. Remove all the dirt stuck to the strainer (7), then wash it in g oil. If the strainer is damaged, shing it, replace O-ring (6) of cover 6. 7. clean diesel oil or flushin replace it with a new part. Install strainer (7) after wa 8. Pour in the specified amou nt of engine oil from oil filler (F) . 9. After refilling, check that t he oil is at the specified level. For details, see "CHECK OIL LEVEL IN TRANSMISSION CASE, ADD OIL (PAGE 4-49)".

akage of oil from the transmission 10. Check that there is no le case or oil filter.