Caterpillar — Engine Stopping

46 Operation Section Engine Stopping Engine Stopping i01057253 Emergency Stopping i01428739 Stopping the Engine SMCS Code: 1000; 7418 SMCS Code: 1000; 7000 NOTICE Emergency shutoff controls are for EMERGENCY use ONLY. DO NOT use emergency shutoff devices or controls for normal stopping procedure. NOTICE Stopping the engine immediately after it has been working under load can result in overheating and ac- celerated wear of the engine components. Ensure that any components for the external system that support the engine operation are secured after the engine is stopped.

If the engine has been operating at high rpm and/or high loads, run at low idle for at least three minutes to reduce and stabilize internal engine temperature before stopping the engine. Emergency Stop Button Avoiding hot engine shutdowns will maximize tur- bocharger shaft and bearing life. Prior to stopping an engine that is being operated at low loads, operate the engine at low idle for 30 seconds before stopping. If the engine has been operating at highway speeds and/or at high loads, operate the engine at low idle for at least three minutes. This procedure will cause the internal engine temperature to be reduced and stabilized. Ensure that the engine stopping procedure is understood.

Stop the engine according to the shutoff system on the engine or refer to the instructions that are provided by the OEM. g00104303 Illustration 28 Typical emergency stop button To stop the engine, turn the ignition key switch to the OFF position. The emergency stop button is in the OUT position for normal engine operation. Push the emergency stop button. The engine will not start when the button is locked. Turn the button clockwise in order to reset.