47 Operation Section Engine Stopping i01646416 Manual Stop Procedure i01465494 After Stopping Engine SMCS Code: 1000 SMCS Code: 1000 Note: Individual applications will have different control systems. Ensure that the shutoff procedures are understood. Use the following general guidelines in order to stop the engine. Note: Before you check the engine oil, do not operate the engine for at least 10 minutes in order to allow the engine oil to return to the oil pan. 1. Remove the load, when possible. Reduce the engine speed (rpm) to low idle. Check the crankcase oil level. Maintain the oil level between the mark and the mark on the oil level gauge. 2.
Increase the engine speed (rpm) to no more than one-half of the rated rpm. Perform this procedure for three to five minutes in order to cool the engine. Reduce the engine speed (rpm) to low idle. If necessary, perform minor adjustments. Repair any leaks and tighten any loose bolts. Note the service hour meter reading. Perform the maintenance that is in the Operation and Maintenance Manual, “Maintenance Interval Schedule”. 3. After the cool down period, turn the key switch to the OFF position. Fill the fuel tank in order to help prevent accumulation of moisture in the fuel. Do not overfill the fuel tank.
NOTICE Only use antifreeze/coolant mixtures recommended in the Coolant Specifications that are in the Operation and Maintenance Manual. Failure to do so can cause engine damage. Allow the engine to cool. Check the coolant level. If freezing temperatures are expected, check the coolant for proper antifreeze protection. The cooling system must be protected against freezing to the lowest expected outside temperature. Add the proper coolant/water mixture, if necessary. Perform all required periodic maintenance on all driven equipment. This maintenance is outlined in the instructions from the OEM.