77 Maintenance Section Battery Electrolyte Level - Check Note: Always recycle a battery. Never discard a battery. Return used batteries to an appropriate recycling facility. A mixture of 0.1 L (0.11 qt) of ammonia and 1 L (1 qt) of clean water Thoroughly rinse the battery case with clean water. 5. Remove the used battery. 6. Install the new battery. Use a fine grade of sandpaper to clean the terminals and the cable clamps. Clean the items until the surfaces are bright or shiny. DO NOT remove material excessively. Excessive removal of material can cause the clamps to not fit properly. Coat the clamps and the terminals with 5N-5561 Silicone Lubricant, petroleum jelly or MPGM grease. Note:
Before the cables are connected, ensure that the key start switch is OFF. 7. Connect the cable from the starting motor to the POSITIVE battery terminal. 8. Connect the cable from the ground plane to the NEGATIVE battery terminal. i01492654 Battery or Battery Cable - Disconnect i01639002 Battery Electrolyte Level - Check SMCS Code: 1402-029 SMCS Code: 1401-535 When the engine is not run for long periods of time or when the engine is run for short periods, the batteries may not fully recharge. Ensure a full charge in order to help prevent the battery from freezing. If batteries are properly charged, ammeter reading should be very near zero.
The battery cables or the batteries should not be removed with the battery cover in place. The bat- tery cover should be removed before any servic- ing is attempted. Removing the battery cables or the batteries with the cover in place may cause a battery explosion resulting in personal injury. All lead-acid batteries contain sulfuric acid which can burn the skin and clothing. Always wear a face shield and protective clothing when working on or near batteries. 1. Turn the start switch to the OFF position. Turn the ignition switch (if equipped) to the OFF position and remove the key and all electrical loads. 1. Remove the filler caps. Maintain the electrolyte level to the mark on the battery.
2. Disconnect the negative battery terminal at the battery that goes to the start switch. Ensure that the cable cannot contact the terminal. When four 12 volt batteries are involved, the negative side of two batteries must be disconnected. If the addition of water is necessary, use distilled water. If distilled water is not available use clean water that is low in minerals. Do not use artificially softened water. 3. Tape the leads in order to help prevent accidental starting. 2. Check the condition of the electrolyte with the 1U-7298 Coolant/Battery Tester ( C) or the 1U-7297 Coolant/Battery Tester ( F). 4. Proceed with necessary system repairs.
Reverse the steps in order to reconnect all of the cables. 3. Keep the batteries clean. Clean the battery case with one of the following cleaning solutions: A mixture of 0.1 kg (0.2 lb) of baking soda and 1 L (1 qt) of clean water