Aegis LH630-775 — Section 8 - Electrical System

Section 8 Electrical System and Components 4. Remove the two thru (larger) bolts. See Figure 8-19. 7. Remove the drive lever pivot bushing and backing plate from the end cap. See Figure 8-22. Figure 8-19. Removing Thru Bolts. Figure 8-22. 5. Remove the commutator end plate assembly, containing the brush holder, brushes, springs, and locking caps. Remove the thrust washer from inside the commutator end. See Figure 8-20. 8. Take out the drive lever and pull the armature out of the drive end cap. See Figure 8-23. 9. Remove the thrust washer from the armature shaft. See Figure 8-23. Figure 8-20. Removing Commutator End Plate Assembly. Figure 8-23. Armature and Lever Removed. 6.

Remove the frame from the armature and drive end cap. See Figure 8-21. 10. Push the stop collar down to expose the retaining ring. See Figure 8-24. Figure 8-21. Starter Frame Removed. 8.14