Aegis LH630-775 — Section 10 - Inspection and Reconditioning

Section 10 Inspection and Reconditioning Camshaft and Crankshaft This section covers the operation, inspection, and repair/reconditioning of major internal engine components. Also included are water pump, cooling system and fan drive belt inspection criteria. The following components are not covered in this section. They are covered in sections of their own: Inspection and Service Inspect the gear teeth of the camshaft and crankshaft. If the teeth are badly worn, chipped, or some are missing, replacement will be necessary. If there is tooth damage on either the camshaft gear or crankshaft gear, both the camshaft and crankshaft must be replaced.

Air Cleaner, Section 4 Carburetor & External Governor, Section 5 Ignition, Charging & Electric Starter, Section 8 Clean all parts thoroughly. Only clean parts can be accurately inspected and gauged for damage or wear. There are many commercially available cleaners that will quickly remove grease, oil, and grime from engine parts. When such a cleaner is used, follow the manufacturer’s instructions and safety precautions carefully. Make sure all traces of the cleaner are removed before the engine is reassembled and placed into operation. Even small amounts of these cleaners can quickly break down the lubricating properties of engine oil. Inspect the bearing surfaces for scoring, grooving, etc.

Measure the running clearance between the bearing journals and their respective bores. Use an inside micrometer or telescoping gauge to measure the inside diameter of both bearing bores in the vertical and horizontal planes. Use an outside micrometer to measure the outside diameter of the bearing journals. Subtract the journal diameters from their respective bore diameters to get the running clearances. Check the results against the specifications in Section 1. If the running clearances are within specification, and there is no evidence of scoring, grooving, etc., no further reconditioning is necessary.

If the bearing surfaces are worn or damaged, the crankcase and/or closure plate will need to be replaced. Use an aerosol gasket remover, paint stripper, or lacquer thinner to remove any old sealant. Apply the solvent, allow time for it to work, and then brush the surface with a brass wire brush. After the old sealant is removed, clean the surface with isopropyl alcohol, lacquer thinner, or aerosol electrical contact cleaner. Do not scrape the surfaces, as any scratches, nicks, or burrs can result in leaks. See Service Bulletin 252 for further information. 10 Inspect the crankshaft keyways. If worn or chipped, replacement of the crankshaft will be necessary.

Inspect the crankpin for score marks or metallic pick up. Slight score marks can be cleaned with crocus cloth soaked in oil. If wear limits, as stated in “Specifications and Tolerances,” are exceeded, it will be necessary to either replace the crankshaft or regrind the crankpin to 0.25 mm (0.010 in.) undersize. If reground, 0.25 mm (0.010 in.) undersize connecting rods (big end) must then be used to achieve proper running clearance. Measure the crankpin for size, taper, and out-of-round. Refer to A Guide to Engine Rebuilding (TP-2150-A) for additional information.

Measurement Guide (TP-2159-B) and Engine Inspection Data Record (TP-2435) are also available; use these to record inspection results. 10.1 Section 10 Inspection and Reconditioning