Aegis LH630-775 — Section 11 - Reassembly

Section 11 Reassembly Figure 11-18. Rotating Crankshaft to Seat Closure Plate. 7. Install the ten hex flange screws securing the closure plate to the crankcase. If a thick flat washer was used on one of the screws, install it in the #10 location. Install the silver plated (ground) screw in its original location (normally the #4 or #6 location). Torque the fasteners, in the torque sequence shown in Figure 11-19 to 24.4 N·m (216 in. lb.) . Figure 11-16. Closure Plate Sealant Pattern. 4. Make sure end of governor cross shaft is lying against the bottom of cylinder #1 inside of the crankcase. See Figure 11-17. 5.

If alignment pins were removed previously, install them in their respective locations in the crankcase. See Figure 11-17. Figure 11-17. Installing Locating Pins. 6. Install the closure plate on the crankcase. Carefully seat the camshaft and crankshaft into their mating bearings. Rotate the crankshaft to help engage the oil pump and governor gear meshes. See Figure 11-18. Figure 11-19. Closure Plate Torque Sequence. 11.7 1 3 10 5 8 7 Plated Screw 6 Location 9 4 2 11