Aegis LH630-775 — Section 11 - Reassembly

Section 11 Reassembly height is obtained. The frictional heat from the engaging threads may otherwise cause the locking compound to set up prematurely. Remove the two nuts. Figure 11-20. Torquing Closure Plate Screws. Install Cylinder Studs NOTE: Do not reinstall or attempt to reuse any cylinder studs that have been removed. Discard any removed stud(s) and replace with new. Figure 11-22. Checking Cylinder Stud Height. 4. Repeat steps 1-3 for each of the studs. If any of the cylinder studs were removed, install new stud(s) as follows: Install Reed and Breather Cover Assembly 1. Make sure sealing surfaces of the crankcase and breather cover are clean and free of all old gasket material.

Clean with an aerosol type gasket remover or cleaning solvent. DO NOT scrape the surfaces as this can result in leakage. 1. Identify the longer threaded end of the new stud containing the Loctite ® Dri-Loc ® . See Figure 11-21. 2. Check to make sure there are no nicks or burrs on the sealing surfaces. 3. Install the breather reed and breather reed retainer onto the crankcase and secure with the hex flange screw. Hold the assembly in line when tightening. Torque the screw to 3.9 N·m (35 in. lb.) . See Figure 11-23. Stud End with Loctite ® Dri-Loc ® Figure 11-21. New Cylinder Stud. 2. Tighten two hex nuts together on the shorter threaded section, with the identification mark on the end. 3.

Thread the end of the stud with the Loctite ® into the crankcase, until an exposed stud height of 75 mm (2 61/64 in.) is obtained. The end with the dash mark must be out . See Figure 11-22. When threading in the studs, use a steady tightening motion, without interruption, until the proper Figure 11-23. Installing Breather Reed. 11.8