Aegis LH630-775 — Section 11 - Reassembly

Section 11 Reassembly Figure 11-43. Test Fitting Pulley. Figure 11-45. Using Grease in O-Ring Groove of Pump Cavity. 2. If the water pump by-pass hose fitting was removed previously, apply pipe sealant with Teflon ® (Loctite ® 59241 or equivalent) on the threads and tighten it into pump. Orient the fitting so the outlet points in the 11 o'clock position as shown in Figure 11-44. Figure 11-46. Installing O-Ring in Groove. 5. Apply rubber lubricant to the inner surfaces of the short hose section. Assemble the hose to the outlet of the water pump and secure with the larger diameter clamp. Orient the clamp so the tangs extend out in the 3 to 4 o'clock position. See Figures 11-47 and 11-48.

Figure 11-44. Water Pump By-pass Fitting. 3. Check the sealing surfaces of the water pump and crankcase. They must be clean and free of any nicks or damage. 4. Apply a small amount of grease in several locations to hold the new water pump O-Ring in place. Install a new O-Ring in the groove of crankcase. See Figures 11-45 and 11-46. Do not use RTV sealant in place of the O-Ring, or attempt to reinstall a used O-Ring. Figure 11-47. Assembling Hose to Water Pump. 11.14