Aegis LH630-775 — Section 11 - Reassembly

Section 11 Reassembly 6. Slide the smaller diameter clamp onto the extruded end of the formed metal tube and insert this end of the tube into the hose section. Position the tube so its formed offset leads down and away from outlet, perpendicular to the pump. Install the clamp onto the hose and position the tangs of the clamp parallel to those of the first clamp. See Figure 11-48. 8. Carefully push the water pump down from the raised position, thereby rotating the tube 90° within the end connections. Guide the pump into position over the O-Ring; aligning the two mounting pins and five screw hole locations. See Figure 11-49.

Start all of the screws, with the longer screw nearest the pump outlet. Torque the screws to 9.9 N·m (88 in. lb.) in the sequence shown in Figure 11-51. Figure 11-48. Transfer Tube, Hose and Water Pump as Assembly. Figure 11-49. Installing Water Pump Assembly. 7. Holding the pump assembly elevated, assemble the transfer tube to the 90° fitting in the crankcase as follows: a. For new/first time tube installation: 1. Place a new ferrule/compression ring in the 90° fitting of the crankcase and loosely install the hex cap onto the threads of the fitting. 2. Insert the plain end of the transfer tube through the hex and compression ring. b. For reinstallation of an existing tube: 1.

Insert the end of transfer tube, with the compression ring, into the 90° fitting of the crankcase. 2. Start the hex cap onto the threaded section of the fitting. IMPORTANT: The 90° fitting in the crankcase is installed and sealed at the factory, in a specific position. Special tools and procedures are involved. Do not loosen, remove, or alter the mounting position of this fitting at any time. 11.15 11 Figure 11-50. Torquing Water Pump Bolts.