Aegis LH630-775 — Section 11 - Reassembly

Section 11 Reassembly 3 5 1 2 6 4 Figure 11-51. Water Pump Torque Sequence. Figure 11-53. Torquing the Hex Cap on Fitting After Pump Installation. NOTE: When installation is complete, the tangs of the two hose clamps should face outward, away from the flywheel and slightly down. See Figure 11-52. 10. Install the drive belt onto the cogged pulley of water pump, then around the cam pulley. Slide the cam pulley, with the belt attached, down onto the keyway end of the camshaft. Be careful not to push the key out of the keyway and/or into the seal when installing the pulley. See Figure 11-54. Figure 11-52. Transfer Tube Hose Clamp(s) Detail. 9.

Push down on the formed tube and hold in this position to prevent it from pivoting upward when tightening the hex cap. Torque the hex cap to 22.6 N·m (200 in. lb.) , to secure the joint connection. Support the fitting with a wrench while torquing, if possible, to prevent applying unnecessary pressure on fitting and joint. See Figure 11-53. Check that the formed tube and hose section have not been pulled up. Figure 11-54. Installing Cam Pulley and Belt. 11. Check or use a feeler gauge to see that there is at least 3.17 mm (0.125 in.) clearance between the underside of the pulley, and the hose, tube, and clamps. Remove the pulley and reposition the tube or clamps if required.

Install the flat washer and hex flange screw, to secure the pulley in place. Torque the screw to 9.9 N·m (88 in. lb.) . See Figure 11-55. 11.16