Aegis LH630-775 — Section 11 - Reassembly

Section 11 Reassembly Figure 11-55. Torquing Mounting Screw of Cam Pulley. Figure 11-57. Torquing the Intake Manifold Screws. Install Intake Manifold Assembly 1. Check that the gasket surfaces of the intake manifold and cylinder heads are clean and free of any nicks or damage. 1 5 6 3 2. Install new intake manifold gaskets onto the port surfaces of the cylinder heads. See Figure 11-56. Intake Gasket 4 2 Figure 11-58. Intake Manifold Torque Sequence. 4. Install and tighten the pipe plug or temperature warning switch, if removed previously from the threaded port of the intake manifold. Use pipe sealant with Teflon ® (Loctite ® 59241 or equivalent) on the threads. Torque to 22.6 N·m (200 in.

lb.) . See Figure 11-59. Figure 11-56. Installing Intake Gaskets. 3. Set the intake manifold, with by-pass hose and wiring harness attached, down into position onto the gaskets and cylinder heads. Install and finger tighten the six hex flange screws in their appropriate locations. Make sure the clamps for the wiring harness are positioned on the long screw on each side. Torque the six intake manifold mounting screws in two steps: first to 7.4 N·m (66 in. lb.) , finally to 9.9 N·m (88 in. lb.) in the sequence shown. See Figure 11-58. Figure 11-59. Plug in Intake Manifold (for Temperature Sensor). 11.17 11