Aegis LH630-775 — Section 11 - Reassembly

Section 11 Reassembly 3. Connect the wire leads to the temperature warning switch, audible alarm, and/or Oil Sentry™ switch, as equipped. 2. Place the stator leads within the clamp and close the loop. See Figure 11-65. Install Stator Assembly 1. Place a small amount of pipe sealant with Teflon ® (Loctite ® 59241 or equivalent) into the holes for the two stator mounting screws. Position the stator assembly onto the mounting studs so the leads are at the bottom, and directed out toward the #1 side, in the 3 o'clock position. Align the mounting holes and install the two hex flange screws. Torque each screw to 6.2 N·m (55 in. lb.) . See Figure 11-63. Figure 11-65.

Routing Stator Leads through Clamp on Adapter. 3. If the violet B+ charge lead is separate from the main harness, secure it to the wiring harness with a tie strap, directly above the clamp. See Figure 11-66. Figure 11-63. Torquing Stator Screws. Install Starter Adapter 1. Install the starter adapter to the crankcase, so the cutout is offset down and facing away from the flywheel side. Install the two mounting screws, and position the clamp for the stator leads on the upper screw. See Figure 11-64. Torque the screws to 15.3 N·m (135 in. lb.) . Figure 11-66. Side View of Stator and B+ Leads Tied to Clamp on Adapter. 11 Install Flywheel WARNING:

Damaging Crankshaft and Flywheel Can Cause Personal Injury! Using improper procedures to install the flywheel can crack or damage the crankshaft and/or flywheel. This not only causes extensive engine damage, but can also cause personal injury, since broken fragments could be thrown from the engine. Always observe and use the following precautions and procedures when installing the flywheel. Figure 11-64. Installing Starter Adapter. 11.19