Aegis LH630-775 — Section 5B - EFI Fuel System

Section 5B EFI Fuel System Service The fuel pumps are non-serviceable and must be replaced if determined to be faulty. If a fuel delivery problem is suspected, make certain the pump is being activated through the relay, all electrical connections are properly secured, the fuses are good, and a minimum of 7.0 volts is being supplied. If during cranking, voltage drops below 7.0 volts, a reduction of fuel pressure may occur resulting in a lean starting condition. If required, testing of the fuel pump and relay may be conducted. 4. If voltage at the plug was good, and there was continuity across the pump terminals, reconnect the plug to the pump, making sure you have a good connection.

Turn on the key switch and listen for the pump to activate. a. If the pump starts, repeat steps 1 and 2 to verify correct pressure. b. If the pump still does not operate, replace it. Fuel Pressure Regulator 1. Connect the black hose of Pressure tester (part of EFI Service Kit, see Section 2) to the test valve in the fuel rail. Route the clear hose into a portable gasoline container or the equipment fuel tank. 2. Turn on the key switch to activate the pump and check the system pressure on the gauge. If a system pressure of 39 psi ±3 is observed, the relay, fuel pump, and regulator are working properly.

Turn the key switch off and depress the valve button on the tester to relieve the system pressure. a. If the pressure is too high, and the regulator is outside the tank (just down line from the pump), check that the return line from the regulator to the tank is not kinked or blocked. If the return line is good, replace the regulator (see ‘‘Regulator Service’’ on page 5B.18). Figure 5B-21. External Fuel Pressure Regulator with Base. General The fuel pressure regulator assembly maintains the required operating system pressure of 39 psi ± 3 . A rubber-fiber diaphragm (see Figure 5B-22) divides the regulator into two separate sections; the fuel chamber and the pressure regulating chamber.

The pressure regulating spring presses against the valve holder (part of the diaphragm), pressing the valve against the valve seat. The combination of atmospheric pressure and regulating spring tension equals the desired operating pressure. Any time the fuel pressure against the bottom of the diaphragm exceeds the desired (top) pressure, the valve opens, relieving the excess pressure, returning the excess fuel back to the tank. b. If the pressure is too low, install in-line ‘‘T’’ between the pump and regulator and retest the pressure at that point. If it is too low there also, replace the fuel pump. 3. If the pump did not activate (step 2), disconnect the plug from the fuel pump.

Connect a DC voltmeter across the terminals in the plug, turn on the key switch and observe if a minimum of 7 volts is present. If voltage is between 7 and 14, turn key switch off and connect an ohmmeter between the terminals on the pump to check for continuity. a. If there was no continuity between the pump terminals, replace the fuel pump. b. If the voltage was below 7, test the wiring harness and relay as covered in the ‘‘Electrical Relay’’ section. 5B.17 5B