Brakes 42 3. Using an ohmmeter, check resistance between the electrical terminal and the metal end cover. See Fig. 9 . Resistance should be 2.0 to 4.0 ohms for a 12-volt/60-watt end cover, and 4.0 to 7.0 ohms for a 24-volt/120-watt end cover. 7. Install the thermostat cover (Ref. 10) as shown in Fig. 9 ; be sure the rubber spacer and gasket are correctly installed. Bendix AD–9 1 2 During cold weather, check operation of the end cover heater-and-thermostat assembly. 3 2 1. With the ignition on, check for voltage to the heater-and-thermostat assembly. Unplug the electrical connector at the air dryer, and place a test lead on each pin of the male connector.
If there is no voltage, look for a blown fuse, broken wires, or corrosion in the vehicle wiring harness. Check that a good ground path exists. 12 13 A 5 4 B 6 10 9 11 8 7 10/11/94 3 8 3 f420016a 2. Check thermostat and heater operation. Turn off the ignition switch and cool the end cover as- sembly to below 40°F (4°C). Using an ohmmeter, check resistance between the electrical pins in the female connector. Resistance should be 1.5 to 3.0 ohms for the 12-volt heater, and 6.8 to 9.0 ohms for the 24-volt heater. Some early models of the AD–9 will have resistance readings of 1.0 to 2.5 ohms for the 12-volt heater, and 4.8 to 7.2 ohms for the 24-volt heater.
If resistance is higher than this, replace the purge-valve housing assembly, which includes the heater-and- thermostat assembly. 1. Heater Post 2. Air Dryer End Cover 3. Thermostat/Terminal Assembly 4. Lockwasher 5. Boot 6. Washer 7. Lockwasher 8. Nut 9. O-Ring 10. Thermostat Cover 11. Screw 12. Thermostat Cover Gasket 13. Spacer Fig. 9, Air Dryer Thermostat Assembly 4. Warm the end cover assembly to over 90°F (32°C) and check resistance as above. Resis- tance should exceed 1000 ohms. 3. Warm the end cover assembly to over 90°F (32°C) and again check resistance. It should ex- ceed 1000 ohms. If it does, the thermostat-and- heater assembly is operating properly.
If it doesn’t, replace the purge-valve housing assem- bly, which includes the heater-and-thermostat assembly. If resistance values are within stated limits, the thermostat and heater are operating properly. If resistance values are outside stated limits, pro- ceed to the next step to determine the cause. 5. With the ignition or engine control switch off, re- move the thermostat cover. See Fig. 9 . Using an ohmmeter, check resistance between the metal end cover and the heater post. For a 12-volt/60- watt end cover, resistance should be 2.0 to 2.8 ohms, and for a 24-volt/120-watt end cover, re- sistance should be 4.0 to 4.6 ohms.
If the heater resistance is outside stated limits, install a new or remanufactured end cover. 42–11 Bendix Air Dryer or Anchorlok Aftercooler Inspecting (Bendix AD–2, AD–4, AD–9, or Anchorlok) 6. Check that a good ground path exists between the air dryer end cover casting and the vehicle chassis. Correct if needed. Bendix AD–2, AD–4, or AD–9 Check reservoirs for moisture. A small amount (tea- spoon or less) is normal. An excess may indicate that desiccant replacement is necessary. If the heater resistance is within stated limits, the thermostat is defective. Replace the thermostat (kit number 102657) or install a new or remanu- factured end cover.
Heavy-Duty Trucks Maintenance Manual, October 2009 42/9