4M41 ENGINE - Injection Nozzle 11B-15-6 (4) Attach the nozzle holder 25 to the nozzle tester A . (5) Pumping the nozzle tester B , measure the 1st valve opening pressure. B 25 Standard value: 17.60 - 18.58 MPa 4ME0519 (6) If the reading deviates from the specified standard value, disassemble the nozzle holder 25 and make pressure adjustment by changing the existing shim 24 for a shim with appropriate thickness. 24 25 Thicknesses of available shims (outside diameter: f 6.2 mm) for 1st valve opening pressure adjustment:
0.40, 0.50, 0.52, 0.54, 0.56, 0.58, 0.60, 0.70 mm 4ME0520 CHECKING FULL LIFT OF NEEDLE VALVE The full lift check is performed to determine if the seat of the nozzle tip 12 is abnormally worn and if the injection nozzle assembly 10 is in order as well. (1) Fit the special tool Gasket and the special tool Plug onto the special tool Retaining Nut (for adjustment). 157892-5100 157892-1600 026508-1140 4ME0521 157892-4400 (2) Fit the nozzle holder 25 to the special tool Plate with its nozzle tip side down. (3) Fit the special tool Holder to the nozzle holder 25 . 25 157944-9520 4ME0522 (4) Mount the special tool Nut on the special tool Holder. 157892-1000 157892-4400 4ME0523 PWEE9409-D E Feb.
2000 Mitsubishi Motors Corporation Added