OPERATING MACHINE 7. Do not allow the breaker chisel to come into contact with the boom when rolling in the arm and the breaker. 8. Change hydraulic oil and replace the full flow filter element at the regular intervals. Hydraulic breaker operation subjects hydraulic oil to become contaminated and/or deteriorated more quickly than bucket operation. Failure to perform proper maintenance of hydraulic oil may cause the base machine and/or the breaker to malfunction. Be sure to change hydraulic oil and replace the full flow filter element at the intervals as shown in the table below to especially extend the service life of the hydraulic pump.
(Refer to the Hydraulic System group in the Inspection and Maintenance chapter.) Watch Out! Take care not to hit the boom with the breaker. M1M7-05-023 Hydraulic Oil change and Full Flow Filter Element Replacement 100% Intervals (Hours) Average Breaker Operating Availability 80% 60% Hours to Replace Hydraulic Oil 40% Hours to Replace Element 20% 2000 1500 1000 500 0 0% Excavator Operating Hours M1M7-05-027 9. Greasing Front Attachment When using a hydraulic breaker, grease all lubrication points on the front attachment every 50 hours of operation. 5-22