hitachi — Hitachi ZX14-3/ZX16-3/ZX18-3/ZX27-3 Hydraulic Excavator Operator's Manual

MAINTENANCE Replace Full Flow Filter --- every 500 hours (first time after 250 hours) d WARNING: Be sure to work only after oil temperature 5 is low or before operation. Failure to do so may allow high temperature oil to spray, possibly causing severe burns. 1. Park the machine on a solid level surface. Position the machine with the arm cylinder fully retracted and the bucket cylinder fully extended. Lower the bucket and blade to the ground. Stop the engine. M1M7-05-024 2. Before replacing the element, be sure to loosen the hydraulic oil tank cap to release the air pressure from the hydraulic oil tank. 2 1 3 3. Loosen four bolts (1) to remove cover (2) and O-ring (3).

While pressing cover (2) down, slowly remove cover (2) so that spring (4) does not fly out. 4 4. Remove spring (4), valve (5) and element (6). 5. Take care not to allow water and/or dirt to enter the filter 5 6. Be careful not to damage element (6) and O-ring (3). Do case. not use a broken element. 6 7. Install new element (6), and O-ring (3) in the hydraulic oil 8. Install cover (2) with four bolts (1). tank. Wrench size : 13 mm Tightening torque : M1MS-07-001 ZX14-3, 16-3, 18-3 : 20 N·m (2 kgf·m, 15 lbt·ft) ZX27-3 : 10 N·m (1 kgf·m, 7.5 lbt·ft) 9. After replacing the element, bleed air from the pump. Check the oil level in the hydraulic oil tank.

(Refer to 7-27 “Bleed Air from Hydraulic System”) If the machine is operated without completely bleeding air from the hydraulic system, damage to the pump may result. 10. Replace the element at the specified interval to keep hydraulic oil clean and extend the service life of hydraulic components. 7-34