CHECKING THE BATTERY Charging method using a constant voltage charger Measure the open-circuit voltage prior to charging. NOTE: Leave the battery unused for more than 30 minutes before measuring its open-circuit voltage. Connect a charger and ammeter to the battery and start charging. NO YES Is the amperage higher than the standard charging amperage written on the battery? Charge the battery until the charging voltage reaches 15 V. This type of battery charger cannot charge an MF battery. A variable voltage charger is recommended. NOTE: Set the charging time to a maxi- mum of 20 hours. Charger Leave the battery unused for more than 30 minutes before measuring its open-circuit voltage.
12.8 V Charging is complete. 12.0 ~ 12.7 V Recharging is required. Under 12.0 V Replace the battery. Ammeter Voltmeter Constant amperage chargers are not suitable for charging MF bat- teries. CAUTION: 3 - 62 CHK ADJ CHK ADJ