volvo — page 69

Electrical system Checking of the regulator Dismantling the diode bridge Special tool: Regulator tester 884892-1 I n order to check the diode bridge and stator windings the diode bridge should be dismantled. Check before testing that the instrument's batteries have the correct voltage. Press in the button "Test" and check that the green lamp ("Batt.") lights. Replace the batteries (2 pcs alkaline, 9 V) if the lamp does not light. Unsolder the three stator windings. Avoid excessive heat since this can damage the diodes. Release the nuts (note how the washers and nuts are fitted). The batteries are in a compartment underneath the in- strument.

Check measurement of the diode bridge Set the multimeter in the position "Diode test". Be very careful to obtain good contact with the probes during all measurements. Connect the tester's grey cables to the carbon. Connect the tester's brown cable to the regulator's yel- l ow and brown cables which should be put together dur- Checking of the B+ diodes i ng the test. Connect the measuring instrument's positive probe to one of the stator winding connections (1-2-3). Connect the instrument's negative probe to the diode plate's B+. Read off the instrument. A normal value should lie be- tween 450 and 650 mV, which is the voltage drop over the diode. An other value indicates a defective diode.

Connect the tester's black cable to the regulator's black cable. Press the "Test" button and at the same time turn the rheostat from the "0" marking to the "1" marking. Check the other B+ diodes by moving the positive probe to the respective connection (1-2-3). Check the B+ diodes in the opposite direction of current flow by switching the position of the positive and neg- ative probes. Carry out the same measurement proced- ure as above. The instrument should during this meas- urement show a one "1" (to far left). If the instrument shows another value the diode is defective. Regulator in good condition The red and green lamps should light from "0".

The red l amp should go off at the "1" marking. Faulty regulator Checking of the B- diodes Replace the regulator if the red lamp lights constantly when the rheostat is turned, or if it does not light in any position. Connect the instrument's positive probe to the diode plate's B- connection and the instrument's negative probe to the respective stator winding connection (1-2-3) Note: The "2" marking on the tester is not used for this type of regulator. Read off the instrument as before. A normal value should lie between 450 and 650 mV. Another value in- dicates a defective diode.

Check measurement of rotor winding After the regulator and carbon brushes have been re- moved it is possible to measure the resistance of the ro- tor. Set the measuring instrument in position Q. Make sure that the probes have good contact between the slip rings. The resistance of the rotor should be 3.0-5.0 Q. Check also that no earth fault occurs by measuring be- tween slip ring and earth. 75