STRUCTURE AND FUNCTION MAIN CONTROL VALVE Boom spool at FLOAT position Operation ! If the work equipment control lever is pushed beyond the LOWER position, boom spool (4) is pushed in to the FLOAT position. ! The oil from the pump passes around the bypass circuit of the bucket spool and flows to the boom spool bypass circuit. The oil in the bypass circuit is sent to the drain circuit by the spool and cannot push open check valve (5). Both the RAISE circuit D and LOWER circuit E of the boom cylinder are connected to the drain circuit, so the boom goes down under its own weight. !
When the bucket is in contact with the ground surface, the bucket can move up or down in accordance with the shape of the ground surface. 10-98