Komatsu — STANDARD VALUE TABLE FOR CHASSIS

TESTING AND ADJUSTING STANDARD VALUE TABLE FOR CHASSIS STANDARD VALUE TABLE FOR CHASSIS 20-4 Machine model WA250-3L Engine model Komatsu S6D102E-1 Item Measurement condition Unit Standard value for new machine Service limit value Engine stall speeds: Torque converter Hydraulic Full C Coolant temperature in operating range C Torque converter oil temperature in operating range C Hydraulic oil at normal operating temperature rpm 2500 ± 100 2500 ± 200 2500 ± 100 2500 ± 200 1900 ± 200 1900 ± 300 Cate gory Item Measurement Condition Unit Standard value for new machine Service limit value Accelerator pedal Operating Force N (kg) 49-98 (5-10) 147 (15) Ë1 Operating Angle Ë2 deg.

48 ± 3 --- 30 ± 2 --- Stopper Height L1 mm 48 ± 5 --- Directional lever N-FORWARD Operating Force N-REVERSE C Engine stopped C Torque converter oil temperature: 60-80EC (140- 176EF) N (kg) 5.9 +4.9, -2.9 (0.6 +0.5, -0.3) 13.7 (1.4) 5.9 + 4.9, -2.9 (0.6 +0.5, -0.3) 13.7 (1.4) N-FORWARD Travel N-REVERSE mm 40 ± 10 40 ± 20 40 ± 10 40 ± 20 Speed lever 1st þ2nd Operating 2ndþ3rd Force 3rdþ4th N (kg) 5.9 +4.9, -2.9 (0.6 +0.5, -0.3) 13.7 (1.4) 5.9 +4.9, -2.9 (0.6 +0.5, -0.3) 13.7 (1.4) 5.9 +4.9, -2.9 (0.6 +0.5, -0.3) 13.7 (1.4) 1st ø 2nd Travel 2nd ø 3rd 3rd ø 4th mm 40 ± 10 40 ± 20 40 ± 10 40 ± 20 40 ± 10 40 ± 20