Komatsu — STANDARD VALUE TABLE FOR ELECTRICAL PARTS

TESTING AND ADJUSTING STANDARD VALUE TABLE FOR ELECTRICAL PARTS STANDARD VALUE TABLE FOR ELECTRICAL PARTS 20-8 Sys- tem Name of Component Connector No. Inspection method Judgment table Measurement conditions Main monitor Alternator Between alternator terminal R and chassis Measure voltage When engine is running (half throttle or above) º 27.5 - 29.5 V i If the battery is old, or after starting in cold, areas, the voltage may not rise for some time. 1) Start engine OHS sensor CNE4 (male) Measure resistance If the condition is as shown in the table below, it is normal. 1) Turn starting switch OFF. 2) Disconnect CNE4. Normal temperature (25EC) Between CNE4 (male) - GND Approx. 2 kS 5EC Approx.

4 kS Speed sensor CNT9 (male) Measure resistance If the condition is as shown in the table below, it is normal. 1) Turn starting switch OFF. 2) Disconnect CNT9. Between (1) - (2) 500 - 1000 S Maintenance monitor Fuel level sensor CNE15 (male) Measure resistance If the condition is as shown in the table below, the sensor is normal. 1) Turn starting switch OFF. 2) Disconnect CNE 15. FULL stopper Between (1) - (2) Approx. 4 S EMPTY 85 S Engine water tem- perature sensor CNE6 (male) Measure resistance If the condition is as shown in the table below, it is normal. 1) Turn starting switch OFF. 2) Disconnect CNE6. 25EC Between (1) - (2) Approx. 40 S 130EC Approx.

1.7 S Torque converter oil temperature sensor CNT9 (male) Measure resistance If the condition is as shown in the table below, the sensor is normal. 1) Turn starting switch OFF. 2) Disconnect CNT9. 25EC Between (1) - (2) Approx. 40 kS 130EC Approx. 1.7 kS Engine water level sensor (radiator water level) CNH6 (male) Continuity If the condition is as shown in the table below, the sensor is normal. 1) Turn starting switch OFF. 2) Disconnect CNH6. Water level normal Between (2) - (1) Continuity Water level abnormal No continuity