Komatsu — JUDGEMENT OF POWER TRAIN

TROUBLESHOOTING JUDGEMENT OF POWER TRAIN JUDGEMENT OF POWER TRAIN To judge if any abnormality in the power train is in the electrical system of the transmission or in the transmission itself, use the following judgement flow chart. If the abnormality is in the electrical system, carry out troubleshooting for E-5, and if the abnormality is in the transmission system, go to troubleshooting T-1 - T-4. Testing transmission solenoid Stop the machine on level ground and install the safety bar on the frame. Lower the bucket to the ground and stop the engine. Then apply the parking brake and put blocks under the wheels to prevent the machine from moving. 1.

Install a T-adapter checker to connector CNFT1, and check the voltage between the connector pins and the chassis ground. 2. Turn the start switch ON. i Do not start the engine under any circumstances. 3. Turn the parking brake switch ON ц OFF (release). 4. When using the foot brake, press the right brake so that the transmission cut-off is not turned off. 20-114 WA250-3L