eng — HANDLING AND PERFORMANCE OF OIL CLINIC FOR OIL, FUEL, COOLANT

. MAINTENANCE OUTLINE OF SERVICE OUTLINE OF SERVICE HANDLING OIL, FUEL, COOLANT,AND PERFORMING OIL CLINIC 4 - 4 OIL Oil is used in the engine and hydraulic equipment under extremely severe conditions (high temperature, high h use. pressure), and deteriorates wit Always use oil that matches the grade and temperature for use given in th e Operation a nd Maintenance Manual. Even if the oil is not dirty, alwa ys change the oil after the specified interv Oil corresponds to blood in th (water, metal particles, dirt, etc The majority of problems with t he machine are caused by the entry of su ch impurities.

Take particular care not to let a ny impurities get in when storing or addin Never mix oils of different grad Always add the specified amo Having too much oil or too little If the oil in the hydraulic oil circ uit of the work equipment becomes murky , the cause m ay be attributed to water or air entered the circuit. Cons ult the Komatsu distributor in your territory When changing the oil, always replace the related filters at the same tim Komatsu oil analysis service i Komatsu distributor in your terr temperature, high FUEL strument, and if fuel containing water or dirt is used, it cannot work properly. impurities get in when storing or adding fuel. n the Operation and Maintenance Manual.

The fuel pump is a precision in strument, and if fuel containing water or d irt is used, it c annot work properly Be extremely careful not to let impurities get in when storing or adding fu Always use the fuel specified i n the Operation and Maintenance Manual Fuel may congeal depending o n the temperature when it is used (particu larly in low te mperature b elow -15 °C (5 °F)). It is necessary to use the fuel that is suitable for the temperature. To prevent the moisture in the air from condensing and forming water insi de the fuel tan k, always fil l the fuel tank after completing the day's work .

Before starting the engine, or w hen 10 minutes have passed after adding fuel, drain the sediment a nd water from the fuel tank. When the machine runs out of f uel, or when a filter element has been repl aced, bleedin g air from th e fue l system is required.