hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting A NO Check the connections of ECM and connector. Faulty ECM. · Key witch: ON YES NO Check the connections of ICF and connector. B harness end of connector is within 120 ± 10 Ω . Faulty ICF. · Key witch: ON YES NO Check the connections of monitor unit and connector. · Key witch: OFF · Key witch: ON Failure in any controller in MC, ICF, ECM or monitor unit. · Key witch: OFF NO Connector ECM Connector (Harness end) ICF Connector ICF-C (Harness end) #C5 T1V1-05-04-002 #C11 T183-05-04-013 T5-6-83 Connect connector in MC. Check if fault A code 11004-2 is displayed. · Key witch: ON NO Check the connections of MC and connector. Faulty MC. YES Connect connector ECM.

Check if fault code YES 11004-2 is displayed. Connect connector in ICF. Check if fault code YES 11004-2 is displayed. Connect connector in ECM. Disconnect connector ICF-C in ICF. Check if resistance between terminals NO Connect connector in ICF. Disconnect connector monitor B in monitor unit. Check if resistance between terminals NO #B6 and #B7 of harness end of connector is within 120±10 Ω. Connect connector in monitor unit. YES Check if fault code 11004-2 is displayed. Faulty monitor unit. YES #B7 #B6