hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting B T5-7-7 Pump 1 Regulator Pressure Sensor Pump 2 Regulator Pressure Sensor Hydraulic Oil Temperature Sensor • Monitors swash angle control pressure of main pump 1. • Monitors swash angle control pressure of main pump 2. • Monitors hydraulic oil temperature. (Overheat prevention control and fan pump flow rate control) • No signals arrive to MC. (Pump control is inoperable.) • No signals arrive to MC. (Pump control is inoperable.) • No signals arrive to MC. • Machine mistracks. • Engine is overloaded. • Work speed is lowered. • Machine mistracks. • Engine is overloaded. • Work speed is lowered.

• Fan pump is fixed at maximum swash angle (fan rotation speed becomes maximum). • Main pump drive torque decreases. Fault Code 11994 is displayed. Fault Code 11992 is displayed. Fault code 11901 is displayed. Monitor Item: Pump 1 Regulator Pressure. Monitor Item: Pump 2 Regulator Pressure. Monitor Item: Hydraulic Oil Temperature - - - - - - • Judge if sensor is faulty or harness is faulty by switching with pump 2 sensor. • Judge if sensor is faulty or harness is faulty by switching with pump 1 sensor. - T2-1 T2-1 T2-1