TROUBLESHOOTING / Troubleshooting B T5-7-10 Parts Fan Pump Control Solenoid Valve Pilot Shut-Off Solenoid Valve MC Function • Controls delivery flow rate of fan pump. (Fan pump flow rate control) • Opens and closes the pilot circuit. • Controls engine, pump and valve operation. Symptoms in control system when trouble oc- curs. • Fan pump flow rate control is not operated. Solenoid valve is closed: • All actuators are not oper- ated. (Pilot pressure oil is not supplied to pilot valve.) Solenoid valve is open: • Pilot pressure oil is always supplied to pilot valve. • When lever is operated with pilot shut-off lever in LOCK position, actuator is operated.
• Pilot pressure oil is not sup- plied to heat circuit in signal control valve. (Actuator con- trollability becomes bad.) • Depending on trouble situa- tions, control system mal- function may differ. (The fol- lowing symptoms in machine operation indicates that MC logic circuit has failed.) Symptoms in machine operation when trouble occurs. Solenoid valve is closed: • Fan pump is fixed at maxi- mum swash angle (maximum flow rate). • As fan pump overload in- creases, delivery flow rates of pumps 1, 2 decrease. Every operation speed becomes slow. Solenoid valve is open: • Fan pump is fixed at mini- mum swash angle (minimum flow rate). • Overheating easily occurs.
• Hydraulic oil temperature easily increases. • Air conditioner does not work easily. Solenoid valve is closed: • All actuators are not oper- ated. (Pilot pressure oil is not supplied to pilot valve.) Solenoid valve is open: • Pilot pressure oil is always supplied to pilot valve. • When lever is operated with pilot shut-off lever in LOCK position, actuator is operated. • Pilot pressure oil is not sup- plied to heat circuit in signal control valve. (Actuator con- trollability becomes bad.) • Even though engine starts, speed stays slow. • As pump displacement is held at minimum, all actuator speeds are slow. Evaluation By MC Fault Code Fault code 11412 is displayed.
- - By Monitor Function Monitor Item: Cooling Fan Pump Proportional Solenoid Valve Current - - Using Test Harness - - - Others - - - NOTE - - • Before suspecting a failure in MC, check the fuses in con- trol system. If any sensor in 5 V system is short-circuited, fault code 11003 is displayed. Descriptions of Control (Operational Principle Section in T/M) T2-1 T2-5 T2-1