TROUBLESHOOTING / Troubleshooting B T5-7-11 Power Digging Switch Travel Mode Switch Auto-Idle Switch • Activates power digging control. ON: 0 V→Increasing Pressure OFF: 5 V→ Not increasing Pressure • Changes travel mode. Fast Mode: 0 V Slow Mode: 5 V • Activates auto-idle control. ON: 0 V → Auto-idle is operable. OFF: 5 V → Inoperable • Open Circuit: Pressure does not in- crease. • Shorted Circuit: Pressure increases for 8 seconds after turning key switch ON, and stops increasing. • Open circuit in switch: Travel speed re- mains unchanged in slow mode (5 V). • Shorted circuit in switch: Travel speed remains unchanged in fast mode (0 V). • Open circuit: Auto-idle system is inoper- able.
• Shorted circuit: Even if auto-idle switch is OFF, auto-idle control is always per- formed. • Power digging control does not operate if open circuit or shorted circuit occurs. • Even if travel mode switch is turned to FAST position, fast travel mode cannot be selected. • Even if travel mode selector is turned to SLOW position, slow travel mode cannot be selected. • Open circuit: Auto-idle system is inoper- able. • Shorted circuit: Even if auto-idle switch is OFF, auto-idle control is always per- formed. - - - Monitor Item: Power Digging Switch Monitor Item: Travel Mode Switch Monitor Item: AI Switch - - - - - - - - - T2-1 T2-1 T2-1