hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting B T5-7-12 Parts Power Mode Switch (HP Mode) Power Mode Switch (E Mode) Power Mode Switch (P Mode) Function • Activates HP mode control. ON: 0 V → HP mode is op- erable. OFF: 5 V → Normal. • Selects E mode. ON: 0 V → E mode OFF: 5 V → Normal • Selects P mode. ON: 0 V OFF: 0 V (If E mode and HP mode are not selected, MC judges as P mode is selected.) Symptoms in control system when trouble oc- curs. • Open circuit: Even if HP mode is selected, HP mode is inoperable. • Shorted circuit: Even if HP mode switch is turned OFF, HP mode is not deactivated. • Open circuit: Even if E mode is selected, engine speed does not decrease. • Shorted circuit:

Engine speed does not increase to the maximum. Auto-idle control is inoperable. • Open circuit: P mode • Shorted circuit: E mode or HP mode Symptoms in machine operation when trouble occurs. • Open circuit: Even if HP mode is selected, HP mode is inoperable. • Shorted circuit: Even if HP mode switch is turned OFF, HP mode is not deactivated. • Open circuit: Even if E mode is selected, engine speed does not decrease. • Shorted circuit: Engine speed does not increase to the maximum. Auto-idle control is inoperable. • Open circuit: P mode • Shorted circuit: E mode or HP mode Evaluation By MC Fault Code - - - By Monitor Function Monitor Item: HP Mode Switch Monitor Item:

E/P Mode Switch Monitor Item: E/P Mode Switch Using Test Harness - - - Others - - - NOTE - - - Descriptions of Control (Operational Principle Section in T/M) T2-1 T2-1 T2-1