TROUBLESHOOTING / Troubleshooting B T5-7-13 Pilot Shut-Off Switch Boom Mode Selector Switch Auto Lubrication Switch • Activates pilot shut-off solenoid valve. (Turns pilot shut-off relay ON.) • Reduces overload relief pressure at the boom cylinder rod side. • Activates auto lubrication. ON: 0 V → Auto lubrication control is op- erable. OFF: 5 V → Inoperable • Open circuit: Pilot shut-off switch is al- ways turned OFF. • Pilot shut-off solenoid valve is not shifted. • Even if lever is operated with pilot shut-off lever in UNLOCK position, all actuator are not operated. • Shorted circuit: Pilot shut-off switch is always turned ON. • Engine does not start.
If shorted circuit occurs while starting en- gine, operate lever with pilot shut-off lever in LOCK position so that actuator is operated. • Open circuit: Boom mode selector control is not performed. • Shorted circuit: Overload relief pressure at the boom cylinder rod side remains low constantly so that machine cannot be raised off ground with front attachment • No signals arrive to MC. • Open circuit: Pilot shut-off switch is al- ways turned OFF. • Pilot shut-off solenoid valve is not shifted. • Even if lever is operated with pilot shut-off lever in UNLOCK position, all actuator are not operated. • Shorted circuit: Pilot shut-off switch is always turned ON. • Engine does not start.
If shorted circuit occurs while starting en- gine, operate lever with pilot shut-off lever in LOCK position so that actuator is operated. • Open circuit: Boom mode selector control is not performed. • Shorted circuit: Overload relief pressure at the boom cylinder rod side remains low constantly so that machine cannot be raised off ground with front attachment • Open circuit, shorted circuit: Auto lubrica- tion is operable. - - - Monitor Item: Pilot Shut-off Switch Monitor Item: Boom Mode Selector Switch Monitor Item: Lubrication Mode - - - - - - - - - T2-5 T2-1 T2-1