hitachi — MC FAULT CODE 11307

TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11307 Open circuit in harness between MC and front attachment pilot pressure sensor. Disconnect connector MC-C of MC. Check for continuity in harnes between terminal #C12 of harness end of connector MC-C in MC and terminal #2 in front attachment pilot pressure sensor is open or shorted. YES YES To A Open circuit in harness between MC and front attachment pilot pressure sensor (terminal #3). NO Switch front attachment pilot pressure sensor with other pressure sensor and retry. Check if fault code disappears. Check if voltage between terminal #1 of harness end of connector in front attachment pilot pressure sensor and machine is specification.

YES · Key switch: ON NO Open circuit in harness between MC and front attachment pilot pressure sensor (terminal #1). NO · Key switch: ON · Specification: More than 0.25 V, Less than 4.75 V Faulty front attachment pilot pressure sensor. YES Check if voltage between terminal #C12 of harness end of connector MC-D and machine is 0 V. YES Faulty MC. A Connector (Harness end of connector viewed from the open side) Shorted circuit in harness between MC and front attachment pilot pressure sensor. · Key switch:

ON NO MC Connector MC-C Pilot Pressure Sensor (Front Attachment) #C12 C23 C31 T5-6-83 Fault Code Trouble Cause Influenced Control 11307-3 Abnormal Front Attachment Pilot Pressure Sensor High Voltage Voltage: 4.75 V or higher • Auto-Idle Control • Idle Speed-Up Control • ECO Control • Travel HP Mode Control • Heater Control • Travel Motor Swash Angle Control 11307-4 Replace Front Attachment Pilot Pressure Sensor Voltage: Less than 0.25 V • Auto-Idle Control • Idle Speed-Up Control • ECO Control • Travel HP Mode Control • Heater Control • Travel Motor Swash Angle Control Disconnect connector of front attachment pilot pressure sensor.

Check if voltage NO between terminals #1 and #3 of harness end of connector is 5±0.5 V. C1 C10 1 2 3