TROUBLESHOOTING / Troubleshooting A PROPORTIONAL SOLENOID VALVE FAILURE MC FAULT CODE 11400 pump2 flow rate limit control solenoid valve. · Between terminal #A16 of connector MC-A in MC and terminal #2 of connector in maximum pump2 flow rate limit control solenoid valve Connector (Harness end of connector viewed from the open side) MC Connector MC-A #A16 #A22 T183-05-04-008 Maximum Pump 2 Flow Rate Limit Control Solenoid Valve T1V1-05-04-003 T5-6-84 Fault Code Trouble Cause Influenced Control 11400-2 Abnormal Current Feedback of Maximum Pump 2 Flow Rate Limit Control Solenoid Valve Current:
Both of Higher than 920 mA or Less than 60 mA Pump 2 Flow Rate Limit Control 11400-3 Abnormal Feedback High Current of Maximum Pump 2 Flow Rate Limit Control Solenoid Valve Current: Higher than 920 mA Pump 2 Flow Rate Limit Control 11400-4 Abnormal Feedback Low Current of Maximum Pump 2 Flow Rate Limit Control Solenoid Valve Current: Less than 56 mA Pump 2 Flow Rate Limit Control Switch connectors of Faulty maximum pump2 maximum pump2 flow NO flow rate limit control rate limit control solenoid valve. solenoid valve and YES torque control solenoid valve. Faulty MC. Check if fault code in torque control solenoid YES Check for continuity in valve is displayed.
harness between MC and maximum pump2 flow rate limit control solenoid valve. · Between terminal #A22 of connector MC-A in MC and terminal #1 of Open circuit in harness. connector in maximum NO Open circuit in harness. NO