Lubrication System Remove, Inspect, and Install Oil Cooler and Oil Filter Bypass Valves NOTE: Refer to OIL FILTER AND OIL CONDITIONING HOUSING ASSEMBLY, earlier in this group, for illustrated location of valves. 02 060 4 Oil cooler bypass valve is in same location on oil cooler cover/valve housing for remote filter applications. Oil filter bypass valve is in same location on face of remote oil filter housing. RG8245C –UN–06DEC97 1. Remove oil cooler bypass valve assembly (A) and oil filter bypass valve assembly (D) from oil filter housing (G). Discard O-rings.
Removing Oil Cooler and Oil Filter Bypass Valve A—Oil Cooler Bypass Valve Assembly D—Oil Filter Bypass Valve Assembly G—Oil Filter Housing 2. Clean all parts with a brass or copper wire brush and solvent. Dry with compressed air. 3. Inspect bypass valves and valve bores for damage. Replace if necessary. 4. Check bypass valve springs for proper compression. Replace if not within specification. Specification New Oil Cooler Bypass Valve Spring—Free Length 44.0 mm (1.73 in.) .................................................... Working Load @ 64—78 N (14— 18 lb-force) 30.0 mm (1.18 in.) ...................................................................
New Oil Filter Bypass Valve Spring—Free Length 44.0 mm (1.73 in.) .................................................... Working Load @ 64—78 N (14— 18 lb-force) 30.0 mm (1.18 in.) ................................................................... 5. Dip all parts in clean engine oil. Insert valve and spring assembly in housing. 6. Install plug using a new O-ring and tighten to specifications. Specification Oil Cooler Bypass Valve Plug— Torque 100 (74 lb-ft) ........................................................................... Oil Filter Bypass Valve Plug— Torque 100 (74 lb-ft) ...........................................................................
CTM100 (06APR04) 02-060-4 P OWER T ECH 10.5 L & 12.5 L Diesel Engines RG,RG34710,210 –19–06NOV00–1/1 040604 PN=272