Observable Diagnostics and Tests Inspect Thermostat and Test Opening Temperature Visually inspect thermostat for corrosion or damage. Replace as necessary. Test thermostat as follows: CAUTION: DO NOT allow thermostat or thermometer to rest against the side or bottom of container when heating water. Either may rupture if overheated. 1. Remove thermostats. See REMOVE THERMOSTATS in Section 02, Group 070. RG5971 –UN–23NOV97 04 150 2. Suspend thermostat and a thermometer in a container of water. 14 3. Stir the water as it heats. Observe opening action of thermostat and compare temperatures with specification given in chart below. Testing Thermostat Opening Temperature NOTE:
Due to varying tolerances of different suppliers, initial opening and full open temperatures may vary slightly from specified temperatures. THERMOSTAT TEST SPECIFICATIONS Initial Opening Full Open Rating (Range) (Nominal) 71 ° C (160 ° F) 69–72 ° C (156–162 ° F) 84 ° C (182 ° F) 77 ° C (170 ° F) 74–78 ° C (166–172 ° F) 89 ° C (192 ° F) 82 ° C (180 ° F) 80–84 ° C (175–182 ° F) 94 ° C (202 ° F) 89 ° C (192 ° F) 86–90 ° C (187–194 ° F) 101 ° C (214 ° F) 90 ° C (195 ° F) 89–93 ° C (192–199 ° F) 103 ° C (218 ° F) 92 ° C (197 ° F) 89–93 ° C (193–200 ° F) 105 ° C (221 ° F) 96 ° C (205 ° F) 94–97 ° C (201–207 ° F) 100 ° C (213 ° F) 99 ° C (210 ° F) 96–100 ° C (205–212 ° F) 111 ° C (232 ° F) 4.
Remove thermostat and observe its closing action as it cools. In ambient air the thermostat should close completely. Closing action should be smooth and slow. 5. If any thermostat is defective on a multiple thermostat engine, replace all thermostats. CTM100 (06APR04) 04-150-14 P OWER T ECH 10.5 L & 12.5 L Diesel Engines RG,RG34710,1548 –19–24SEP02–1/1 040604 PN=362