John Deere 450DLC — Main Controller (MCF) Circuit Theory of Operation

TM2361 (24JUN08) 9015-15-27 450DLC Excavator Operation and Tests 062608 PN=471 Sub-System Diagnostics When any other hydraulic functions is combined with When the coolant temperature and/or hydraulic oil the swing function, the MCF will send more current to temperature decrease to less than the overheat pump 1 control solenoid (Y12) to increase delivery flow (decreasing) specification, the MCF will increase the of pump 1. pump flow rate back to normal. Overheat Prevention Control:

When coolant and Specification hydraulic oil temperatures reach a specified level, Coolant and Hydraulic Oil Overheat (Increasing)— maximum flow rate and suction torque of the main Temperature................................................................................ 99°C pumps are reduced to prevent overheating. 210°F Coolant and Hydraulic Oil MCF inputs involved: Overheat (Decreasing)— Temperature................................................................................ 95°C 203°F • Hydraulic oil temperature sensor (B40) Hydraulic Oil Temperature • ECM (through CAN) [coolant temperature sensor Sensor (B40)—Resistance...............

14 600—17 800 ohms @ -20°C (B43)] (-4°F) • Pump 1 delivery pressure sensor (B35) Hydraulic Oil Temperature • Pump 1 control pressure sensor (B36) Sensor (B40)—Resistance................. 5880 ohms (approximately) @ 0°C (32°F) • Pump 2 delivery pressure sensor (B37) Hydraulic Oil Temperature • Pump 2 control pressure sensor (B38) Sensor (B40)—Resistance.......................2210—2696 ohms @ 20°C (68°F) MCF outputs involved: Hydraulic Oil Temperature Sensor (B40)—Resistance................. 1140 ohms (approximately) @ 40°C (104°F) • Pump 1 control solenoid (Y12) Hydraulic Oil Temperature • Pump 2 control solenoid (Y13) Sensor (B40)—Resistance...................

534 ohms (approximately) @ 60°C (140°F) The MCF determines the actual swash plate angle Hydraulic Oil Temperature from signals received from pump control pressure Sensor (B40)—Resistance................... 322 ohms (approximately) @ 80°C (176°F) sensors (B36 and B38) (terminals D11 and D4). The MCF determines the target swash plate angle from Fan Pump Flow Control: The fan pump flow circuit signals received from pump delivery pressure sensors controls fan speed by controlling delivery flow rate of (B35 and B37) (terminals C3 and C12).

the fan pump according to boost temperature (intake air temperature passing by the intercooler), engine The MCF continually compares signals from the pump coolant temperature, engine intake air temperature, control pressure sensors to signals from the pump and hydraulic oil temperature. delivery pressure sensors. MCF inputs involved:

When the coolant temperature and/or hydraulic oil temperature reach the overheat (increasing) • Engine speed dial (R15) specification, as detected by coolant temperature • Hydraulic oil temperature sensor (B40) sensor (B43) and hydraulic oil temperature sensor • A/C controller (A7) (blower motor relay control) (B40), the MCF compares the actual swash plate • ECM (through CAN) angle with the target swash plate angle, then sends the appropriate amount of current to pump control MCF output involved: Fan pump control solenoid (Y14) solenoids (Y12 and Y13) to decrease the maximum pump flow rate and torque by 7 percent. Continued on next page CS33148,00008EB –19–28APR06–10/15 9015 15 27